logo
Shanghai Haohai Biological Technology Co., Ltd.
E-mail office@universeiol.com Telefono: 86-0371-67897062-8008
Casa. > prodotti > Lente intraoculare idrofila >
Moist Heat Sterilization Method Monofocal Lens Type Intraocular Lens Offering Stable Optical Clarity And Surgical Outcomes
  • Moist Heat Sterilization Method Monofocal Lens Type Intraocular Lens Offering Stable Optical Clarity And Surgical Outcomes

Moist Heat Sterilization Method Monofocal Lens Type Intraocular Lens Offering Stable Optical Clarity And Surgical Outcomes

Place of Origin China
Marca Henan Universe IOL
Certificazione ISO13485&ISO9001
Model Number PCF60/A
Dettagli del prodotto
Nome del prodotto:
Lente intraoculare idrofila
Modello:
PCF60/A
Progettazione ottica:
Asferico
Materiale:
Acrilico idrofilo
Diametro totale:
12,5 mm
Diametro ottico:
6,0 mm
Progettazione dei bordi:
Design con bordo quadrato a 360°
Una costante:
118.4
Termini di trasporto & di pagamento
Quantità di ordine minimo
1000 pezzi
Prezzo
Negoziabile
Termini di pagamento
T/T
Descrizione del prodotto

Product Description:

The Hydrophilic Intraocular Lens Model PCF60/A represents a state-of-the-art solution designed for patients requiring lens replacement due to cataracts or other ocular conditions. This advanced monofocal lens is engineered to provide exceptional visual clarity and improved quality of life by restoring vision with precision and reliability. Featuring an aspherical optical design, the PCF60/A lens significantly reduces spherical aberrations, resulting in sharper and more natural vision for patients, especially in low-light conditions.

One of the key attributes of the PCF60/A lens is its hydrophilic composition, which ensures excellent biocompatibility and flexibility. This material characteristic allows the lens to be folded easily during implantation, facilitating a minimally invasive surgical procedure and promoting faster recovery times. The hydrophilic nature of the lens also contributes to its durability and long-term stability within the eye, minimizing the risk of postoperative complications.

The PCF60/A intraocular lens features a refractive index of 1.47, which is carefully calibrated to optimize light transmission and refraction within the eye. This refractive index plays a critical role in enhancing visual acuity and contrast sensitivity, ensuring patients achieve clear and vivid vision after surgery. Additionally, the power range of the lens spans from -10 to +37 diopters, providing a wide selection of corrective strengths to accommodate various degrees of refractive errors, including myopia and hyperopia.

With an overall length of 12.5mm, the hydrophilic intraocular lens is designed to fit securely within the capsular bag of the eye. This precise sizing contributes to the stability and centration of the lens post-implantation, which is essential for optimal visual outcomes. The lens's monofocal design means it is specifically tailored to provide excellent distance vision, making it an ideal choice for patients seeking clear, focused vision for everyday activities such as driving and reading from a distance.

In terms of sterilization, the PCF60/A lens undergoes a stringent moist heat sterilization process. This method ensures that the lens is completely free of contaminants and safe for implantation, adhering to the highest standards of medical safety and hygiene. Moist heat sterilization is particularly effective in maintaining the integrity and performance of the hydrophilic material, preserving the lens’s optical properties and mechanical strength.

The aspherical optical design incorporated in the PCF60/A lens is a standout feature that differentiates it from traditional spherical lenses. By correcting for spherical aberrations, this design enhances the quality of vision by reducing distortions and improving contrast sensitivity. Patients implanted with this lens often report better night vision and reduced glare, which are common issues with conventional intraocular lenses.

Moreover, the monofocal nature of the PCF60/A lens provides a dependable and straightforward solution for cataract surgery. While it primarily focuses on delivering sharp distance vision, it allows for the possibility of using additional corrective measures such as glasses for near tasks, depending on the patient’s lifestyle and preferences. This flexibility makes the PCF60/A a versatile option for a broad range of patients.

In summary, the Hydrophilic Intraocular Lens Model PCF60/A combines innovative material science with advanced optical engineering to offer a reliable, high-performance solution for vision correction. Its aspherical optical design, wide power range, optimal refractive index, and safe sterilization method collectively contribute to superior postoperative outcomes. Patients and surgeons alike can trust the PCF60/A lens for its precision, safety, and ability to restore clear, natural vision effectively.

 

Features:

  • Product Name: Hydrophilic Intraocular Lens
  • Material: Hydrophilic Acrylic
  • Refractive Index: 1.47
  • Model: PCF60/A
  • Diameter: 6.0 mm
  • Overall Length: 12.5 mm
  • Foldable Lens for easy implantation
  • Zero spherical aberration for enhanced visual clarity
  • Monofocal design for clear vision at a single focal point
 

Technical Parameters:

Product Name Hydrophilic Intraocular Lens
Material Hydrophilic Acrylic
Model PCF60/A
Sterilization Method Moist Heat
Haptic Angulation
Diameter 6.0 mm
Overall Length 12.5 mm
Refractive Index 1.47
Total Diameter 12.5 mm
Power Range -10 to +37 D
 

Applications:

The Henan Universe IOL Hydrophilic Intraocular Lens, model PCF60/A, is a state-of-the-art foldable lens designed for use in various ophthalmic surgical procedures, particularly cataract surgery. Originating from China, this advanced intraocular lens boasts an aspherical optical design that significantly improves visual quality by minimizing optical aberrations. Its zero spherical aberration feature ensures that patients experience sharp and clear vision post-implantation, making it an excellent choice for those seeking enhanced visual outcomes.

This hydrophilic intraocular lens is ideal for implantation in patients requiring precise refractive correction within a wide power range of -10 to +37 diopters. The overall length of 12.5mm and a haptic angulation of 5° facilitate stable positioning within the capsular bag, reducing the risk of lens decentration and ensuring long-term visual stability. The refractive index of 1.47 contributes to optimal light transmission and clarity, enhancing the visual experience.

The foldable nature of the Henan Universe IOL PCF60/A allows for minimally invasive surgical techniques, enabling surgeons to insert the lens through a small incision. This results in faster recovery times and reduced postoperative complications for patients. Its hydrophilic material ensures excellent biocompatibility, reducing the likelihood of inflammation or adverse reactions after implantation.

The Henan Universe IOL is particularly suitable for patients undergoing cataract extraction who desire high-quality vision with reduced spherical aberrations. It is also appropriate for individuals needing refractive lens exchange or other intraocular lens replacement procedures. The zero spherical aberration and aspherical optical design make this lens especially beneficial for patients with high visual demands, including those involved in activities requiring sharp focus and contrast sensitivity.

In summary, the Henan Universe IOL PCF60/A hydrophilic intraocular lens is a highly versatile and reliable choice for ophthalmic surgeons and patients alike. Its foldable lens structure, zero spherical aberration, and aspherical optical design collectively contribute to superior visual outcomes across a variety of clinical scenarios, ensuring patient satisfaction and improved quality of life.

Contattici in qualunque momento

86-0371-67897062-8008
Torcia che costruisce A, viale di no. 8 Guohai., Zhengzhou, Henan 450001, Cina
Inviaci direttamente la tua richiesta.